Professional Vs non-Professional DVD Writing Quality Tests
9. TTH 02
Review Pages
LiteOn LH-20A1P - burning at 18X
-The reading process
-KProbe test
-DaTARIUS scan
-Comparison Chart
Kprobe | DaTARIUS Analyzer | |
---|---|---|
PI Max | 443 |
1333 |
PI Average | 54.27 |
338 |
PIF Max | 16 |
332 |
PIF Average | 0.40 |
16 |
We see here another example where the trends for both PI and PIF are the same with both KProbe and the DaTARIUS Analyser but there is again a big difference in the actual levels.
Review Pages