Professional Vs non-Professional DVD Writing Quality Tests
15. DAXON AZ3
Review Pages
Pioneer DVR-112D - burning at 12X
-The reading process
-KProbe test
-DaTARIUS scan
-Comparison Chart
Kprobe | DaTARIUS Analyzer | |
---|---|---|
PI Max | 13 |
47 |
PI Average | 1.71 |
15 |
PIF Max | 2 |
33 |
PIF Average | 0.01 |
5
|
The measurements are comparable this time, although the reported PIF level from Kprobe is lower than the corresponding from the DaTARIUS system.
Review Pages