Error Correction Tests
In the following tests we examine the error correction capabilities of the
MSI MS-8152.
- EAC CD-R Test Disc
- Test Results (Max Reading)
|
Errors total
|
Num: 466139
|
|
Errors (Loudness) dB(A)
|
Num: 16452
|
Avg: -64.7 dB(A)
|
Max: -7.7 dB(A)
|
|
Error Muting Samples
|
Num: 504
|
Avg: 7.8 Samples
|
Max: 569 Samples
|
|
Skips Samples
|
Num: 0
|
Avg: 0 Samples
|
Max: 0 Samples
|
|
Total Test Result
|
77.8 points (of 100.0 maximum)
|
The errors within the black triangle defect reached -7.7dB in specific areas
and gave an average of -64.7dB(A). The five scratches also produced errors of
the same approximately level. The score is 77.8 out of 100 (max), which is considered
as average for a CD-ROM drive.
- ABEX TCD-721R
- Test Results (Max speed)
|
Errors total
|
Num: 1641090
|
|
Errors (Loudness) dB(A)
|
Num: 71562
|
Avg: -69.9 dB(A)
|
Max:-8.0 dB(A)
|
|
Error Muting Samples
|
Num: 4980
|
Avg: 1.9 Samples
|
Max: 563 Samples
|
|
Skips Samples
|
Num: 0
|
Avg: 0 Samples
|
Max: 0 Samples
|
|
Total Test Result
|
75.4 points (of 100.0 maximum)
|
The score with the TCD-721R test disc was 75.4. The drive didn't skip any sample,
and but gave many muted samples, while it kept the average error rate at -69.9
dB(A).
- ABEX TCD-726
- Test Results (Max Speed)
|
Errors total
|
Num: 29223162
|
|
Errors (Loudness) dB(A)
|
Num: 146544
|
Avg:-28.7 dB(A)
|
Max:-6.4 dB(A)
|
|
Error Muting Samples
|
Num: 150231
|
Avg: 45.7 Samples
|
Max: 3584 Samples
|
|
Skips Samples
|
Num: 10
|
Avg: 792.7 Samples
|
Max: 2939 Samples
|
|
Total Test Result
|
51.1 points (of 100.0 maximum)
|
The drive didn't perform very well with the TCD-726 test disc. The problem
is that the defects and fingerprints caused many errors and muting samples.
As it seems the drive cannot handle well defects and fingerprints. The total
score for the test is 51.1 points out of 100 (max).
- Conclusion
|
Test Disc
|
Reading Speed
|
Score
|
|
EAC CD-R
|
Max
|
77.8
|
|
ABEX TCD-721R
|
75.4
|
|
ABEX TCD-726
|
51.1
|
|
Average Score
|
62.56
|
The MSI MS-8152 gets an average score of 68.10 out of 100 in the reading
error correction tests.
- C2 Information accuracy
- Tests Results (Max Speed)
The drive gave a 99.81% C2 accuracy with the ABEX TCD-721R test disc and an
81.9 quality score. The EAC C2 % accuracy results are not different with the
EAC CD-R and the ABEX TCD-726 test discs.
|
Test Disc
|
Reading Speed
|
Score (%)
|
|
EAC CD-R
|
Max
|
99.7
|
|
ABEX TCD-721R
|
99.7
|
|
ABEX TCD-726
|
62.9
|
|
Average Score
|
87.43
|